Customization: | Available |
---|---|
Warranty: | One Year |
Max Diameter of Workpiece: | <500mm |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Steel rod | (300±3)mm length, 6mm diameter,with flat end face that is perpendicular to its longitudinal axis. |
Heat source | Heat one end of the rod over a length of at least 50mm a temperature of (650±20)ºC |
Thermocouple | Type K |
Timing device | 9999X0.1s |
Thermoneter | To check the temperature 20 mm from the heated end is (650±20)ºC of the rod. |
Operation mode | By button, apply heat end of the rod against the surface of the hearing protector with the force exerted by its own mass, for a period of (5.0±0.5)s |
Tester size | 540*250*880mm |
Power supply | 220V50Hz other voltages request. |