Conductor Pull Test Apparatus
Product details:ZLT-CT1
To test the connection reliability of wires in sockets,or solid copper wires in threaded terminals,in accordance with IEC 60884 clause 13.4 and figure 46.
The conductor is pushed as far as possible into the terminal under test or is inserted so that adequate connection is obvious.
A test probe according to IEC 61032 test probe 1 is pushed against the connecting or disconnecting means with a force of 120 N in the direction opposite to the mounting direction as described in Figure 46a.
During the application of the force, the conductor, except for lead wires of pilot lights, is subjected to a pull of 30 N; the pull is applied in one smooth and continuous motion, for 1 min, in the direction of the longitudinal axis of the conductor space.
During the application of the pull, the conductor shall not come out of the screwless terminal. The force of 120 N has to be applied before the force of 30 N is applied. The force of 30 N is maintained on the conductor during the complete test.
Standard Outfit:
1 sets weights,30N-120N.
1 test probe 1.
1 adjustable rotation angle mechanism.