Horizontal Vertical Flame Chamber of UL94 Testing Equipment

Product Details
Customization: Available
Warranty: One Year
Max Diameter of Workpiece: <500mm
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
20
Year of Establishment
1999-04-01
  • Horizontal Vertical Flame Chamber of UL94 Testing Equipment
  • Horizontal Vertical Flame Chamber of UL94 Testing Equipment
  • Horizontal Vertical Flame Chamber of UL94 Testing Equipment
  • Horizontal Vertical Flame Chamber of UL94 Testing Equipment
  • Horizontal Vertical Flame Chamber of UL94 Testing Equipment
  • Horizontal Vertical Flame Chamber of UL94 Testing Equipment
Find Similar Products

Basic Info.

Model NO.
ZLT-UL94
Mass Scope of Workpiece
<900kg
Type
Flammability Tester
Accuracy Grade
0.5
Load Way
Mechanical Load
Display
Digital
Control
Electricity
Weight
100-500Kg
Power Source
AC220V
Usage
Test Comparing Burning Behaviour for UL94
Certification
CNAS Calibration Provided
Material
Stainless Steel
MOQ
1 PC
Delivery
in 25-30 Days
Transport Package
in Plywood Carton
Specification
Horizontal-Vertical Flame Chamber Tester
Trademark
ZLTJC
Origin
Guangzhou, Guangdong, China
HS Code
9031809090
Production Capacity
Stock Available

Packaging & Delivery

Package Size
129.00cm * 71.00cm * 148.00cm
Package Gross Weight
140.000kg

Product Description

Horizontal Vertical Flame Tester

The ZLT Horizontal Vertical Flame Chamber Tester is a fully automatic instrument contained in its own cabinet to maximize the safety of the operator. It screening procedure for comparing the relative burning behaviour specimens made from plastic and other non-metallic materials, exposed to a flame ignition source of 50W or 500W nominal power.

These test methods determine the linear burning rate and the afterflame/afterglow times, as well as the damaged length of specimens. They are applicable to solid and cellular materials that have an apparent density of not less than 250kg/m3, determined in accordance with ISO845. Then do not apply to materials that shrink away from the applied flame without ignitiong; ISO9773 should be used for thin flexible materials. And it's the combustion test device of plastic materials represented by UL-94. It can perform each test of HB, V0 to V2, 5V and VTM, HBF.

Includes: Flame height gauge and 100% absorbent cotton
 
Model  ZLT-HV50 ZLT-HV500 ZLT-HV1000 ZLT-UL94
Test  Flame 50W(burning  test  for  V-0, V-1, V-2  classification) 500W(burning  test  for  5VA, V5VB  classification) 1000W 50W  and  500W
Burner  Tube Internal  diameter:   Φ 9.5mm± 0.3mm,   length: 100mm± 10mm Internal  diameter:   Φ   9.5mm± 0.3mm,   length: 100mm± 10mm Internal  diameter:   Φ   12mm± 0.1mm,   length: 110mm± 0.1mm Internal  diameter: Φ   9.5mm± 0.3mm,   length: 100mm± 10mm
Burning  Angle 0° , 20° , 45° 0° , 20° , 45° 0° , 20° , 45° 0° , 20° , 45°
Thermocouple Type  K  (Ni/Cr  -  Ni/Al) Type  K  (Ni/Cr  -  Ni/Al) Type  K  (Ni/Cr  -  Ni/Al) Type  K  (Ni/Cr  -  Ni/Al)
Thermocouple  Size  O/D  0.5  mm 0.5  mm 0.5  mm 0.5  mm
Standard  Copper  Block  Φ 5.5mm± 0.01mm,   weight: 1.76g± 0.01g  before  drilling.   Cu-ETP Φ 9mm± 0.01mm,   weight: 10g± 0.05g  before  drilling.   Cu-ETP Φ 9mm± 0.01mm,   weight: 10g± 0.05g  before  drilling.   Cu-ETP Φ 5.5mm± 0.01mm,   weight: 1.76g± 0.01g  before  drilling.   AndΦ 9mm± 0.01mm,   weight: 10g± 0.05g  before  drilling. Cu-ETP
Time  for  Temperature  to  Increase From  100° C± 5° C  to  700° C± 3° C;   44s± 2s  (preset) From  100° C± 5° C  to  700° C± 3° C;   54s± 2s  (preset) From  100° C± 5° C  to  700° C± 3° C;   45s± 5s  (preset) From  100° C± 5° C  to  700° C± 3° C;   54s± 2s  and  54s± 2s(preset)
Overall  Height 18mm~22mm(adjustable) 38mm~42mm(adjustable) 50mm~60mm(adjustable) 20± 2mm/40± 2mm(adjustable)
Gas  Supply(do  not  provide) methane, min. 98%  purity methane, min. 98%  purity propane, min. 98%  purity,   and  air methane, min. 98%  purity
Flowmeter 105± 10ml/min 965± 30ml/min 650± 30ml/min, 10± 0.5l/min 105± 10ml/min  and        965± 30ml/min
Manometer 0KPa  to  7.5KPa 0KPa  to  7.5KPa 0  MPa  to  0.1MPa 0KPa  to  7.5KPa
Input  Power 220  V  50  Hz  3A  or  115  V  60Hz  Optional 220  V  50  Hz  3A  or  115  V  60Hz  Optional 220  V  50  Hz  3A  or  115  V  60Hz  Optional 220  V  50  Hz  3A  or  115  V  60Hz  Optional
Volume  Of  Chamber > 0.75m³ ,   black  interior > 0.75m³ ,   black  interior > 1m³ ,   black  interior > 0.75m³ ,   black  interior
Outer  Dimensions W*D*H=1192*580*      1190mm W*D*H=1192*580*
1190mm
W*D*H=1220*700    *1500mm W*D*H=1192*580*
1190mm
Conform  to  standard UL94, IEC60695-11-4,
IEC60695-11-10
UL94, IEC60695-11-3,
IEC60695-11-20                               
IEC60695-11-2 UL94, IEC69695-11-3/4,       IEC60695-11-10/20
Horizontal Vertical Flame Chamber of UL94 Testing Equipment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now